← A-Level Chemistry · Edexcel · A-Level Chemistry revision
⭐ 0
Edexcel A-level Chemistry (9CH0) · Topic 5: Formulae, Equations and Amounts of Substance (part 2)
Mini-Lesson

Formulae, Equations and Amounts of Substance (part 2)

5 missions. Guess, learn, then check. Your place is saved.

  1. Mission 1How can you titrate a tablet that won't even dissolve in water?
  2. Mission 2Why does the same balance give a less trustworthy result when you weigh a tiny amount?
  3. Mission 3Mix 10 g of hydrogen with 10 g of oxygen. Which runs out first?
  4. Mission 4Can a reaction with a 100% yield still turn most of its reactants into waste?
  5. Mission 5Why would a chemist pick a glass tube with just one mark over one marked all the way up?
Mission 1

Mission 1: How can you titrate a tablet that won't even dissolve in water?

Make a guess: How can you titrate a tablet that won't even dissolve in water?

Mission 1

When you can't titrate directly

Back titration flowacid added (known excess)acid that reactedwith CaCO₃left overin the flaskCaCO₃ in tabletNaOH
  • Some samples can't go straight into a titration: an insoluble solid (CaCO3, MgO), a slow reaction, or no sharp end point.
  • Back titration: add a known excess of a standard acid. The solid reacts completely.
  • Then titrate the leftover acid with a standard alkali.
  • Acid that reacted = acid added − acid left over.
Mission 1

Worked example: an indigestion tablet

Back titration flowacid added: 0.02500 mol HClreacted with CaCO₃0.01604 molleft over0.00896 mol÷ 2CaCO₃ : HCl= 1 : 2CaCO₃0.00802 molNaOHHCl : NaOH = 1 : 1
  • A 1.250 g tablet (active ingredient CaCO3) is added to 50.0 cm³ of 0.500 mol dm⁻³ HCl. The leftover acid needs 22.40 cm³ of 0.400 mol dm⁻³ NaOH.
  • CaCO3(s) + 2HCl(aq) → CaCl2(aq) + H2O(l) + CO2(g). Assume nothing else in the tablet reacts with acid.
  • Acid added: 0.500 × 0.0500 = 0.02500 mol.
  • Acid left: n(NaOH) = 0.400 × 0.02240 = 0.00896 mol (HCl : NaOH = 1 : 1).
  • Acid reacted: 0.02500 − 0.00896 = 0.01604 mol.
  • n(CaCO3) = 0.01604 ÷ 2 = 0.00802 mol; mass = 0.00802 × 100.1 = 0.803 g = 64.2% of the tablet.
Quick check
?In a back titration, an insoluble carbonate is added to excess hydrochloric acid, and the leftover acid is titrated with sodium hydroxide. Which amount equals the moles of HCl that reacted with the carbonate?
Mission 1

Dilutions and portions

Dilution and portion250.0 cm³volumetricflaskpipette25.0 cm³conical flaskmoles:totalmoles:total ÷ 10
  • A solution is made up to 250.0 cm³ in a volumetric flask. A 25.0 cm³ portion is pipetted out and titrated.
  • The portion holds one tenth of the total moles. Scale back up: × 10.
  • Diluting changes concentration, not moles: c1V1 = c2V2.
  • Track moles through every step. Scale at the right moment, and say what each number is the moles of.
Quick check
?10.0 cm³ of vinegar is diluted to 100.0 cm³ in a volumetric flask. A 25.0 cm³ portion needs 20.75 cm³ of 0.100 mol dm⁻³ NaOH. CH3COOH + NaOH → CH3COONa + H2O. What was the concentration of ethanoic acid in the original vinegar, in mol dm⁻³?
Calculate

Limestone purity

?1.25 g of powdered limestone is added to 50.0 cm³ of 1.00 mol dm⁻³ HCl (excess). When the fizzing stops, the mixture is made up to 250.0 cm³. 25.0 cm³ portions need a mean titre of 27.50 cm³ of 0.100 mol dm⁻³ NaOH. Calculate the percentage by mass of CaCO3 in the limestone. (Aᵣ: C 12.0, O 16.0, Ca 40.1)
Mission check

?An impure sample of magnesium oxide, an insoluble base, is analysed by back titration. MgO(s) + 2HCl(aq) → MgCl2(aq) + H2O(l). Assume the impurities do not react with acid.
  • 0.400 g of the sample is added to 25.0 cm³ of 1.00 mol dm⁻³ HCl (excess). The leftover acid needs 14.30 cm³ of 0.500 mol dm⁻³ NaOH. What is the percentage by mass of MgO in the sample? (Aᵣ: O 16.0, Mg 24.3)
Mission 2

Mission 2: Why does the same balance give a less trustworthy result when you weigh a tiny amount?

Make a guess: Why does the same balance give a less trustworthy result when you weigh a tiny amount?

Mission 2

Every reading has an uncertainty

Reading a burette and a balance23.024.023.4023.50reading23.45 cm3±0.05 cm35.00 gbalance±0.005 g
  • No measurement is exact: the uncertainty is the range either side of the reading where the true value probably lies.
  • Scale with marks: usually ± half the smallest division. Burette marks every 0.10 cm³ → ±0.05 cm³ per reading.
  • Digital display: usually ± half the last digit (or the value printed on the instrument). Balance to 0.01 g → ±0.005 g.
  • Exam questions often give you the uncertainty: use it.
Mission 2

Percentage uncertainty

  • % uncertainty = uncertainty ÷ measured value × 100.
  • A mass "by difference" uses two readings: ±0.005 + ±0.005 = ±0.01 g.
  • Weigh out 5.00 g: 0.01 ÷ 5.00 × 100 = 0.2%.
  • Weigh out 0.10 g: 0.01 ÷ 0.10 × 100 = 10%.
  • Same balance, same ±0.01 g: the smaller the quantity, the bigger the % uncertainty.
Mission 2

Worked example: a titre

  • Burette: start 1.20 cm³, end 24.65 cm³.
  • Titre = 24.65 − 1.20 = 23.45 cm³.
  • Two readings, each ±0.05 cm³ → titre ±0.10 cm³.
  • % uncertainty = 0.10 ÷ 23.45 × 100 = 0.43%.
  • A 10 cm³ titre would carry 1.0%: bigger titres are better.
Mission 2

Combining and minimising uncertainty

  • Multiplying or dividing measurements? Add their % uncertainties.
  • Example: 1.25 g (±0.01 g) made up to 250.0 cm³ (flask ±0.3 cm³).
  • Mass: 0.01 ÷ 1.25 × 100 = 0.80%. Volume: 0.3 ÷ 250.0 × 100 = 0.12%.
  • Concentration: 0.80 + 0.12 = 0.92%.
  • To minimise % uncertainty: measure larger quantities (more mass, bigger titres, bigger temperature changes) or use more precise apparatus.
Quick check
?A burette reading has an uncertainty of ±0.05 cm³. A student's titre is 12.50 cm³, found from two readings. What is the percentage uncertainty in the titre?
Mission 2

Accuracy, precision and errors

Accuracy and precision on four targetsaccurateand preciseprecise,not accuratesystematic erroraccurate on average,not preciserandom errorneitherbullseye = true value
  • Accurate: close to the true value.
  • Precise: repeat readings close to each other.
  • Repeatable: same method, same person, similar results. Reproducible: different people or methods, similar results.
  • Random error: readings scatter either way. Repeats and a mean reduce its effect.
  • Systematic error: every reading shifted the same way (e.g. heat lost to the air, reading the top of the meniscus). Repeats do not remove it: change the method.
Mission 2

How far from the true value?

  • Compare your result with the accepted (data-book) value.
  • % difference = |your value − accepted value| ÷ accepted value × 100.
  • Edexcel calls this the measurement error (as a percentage error).
  • Example: ΔcH⦵ of ethanol measured as −1020 kJ mol⁻¹; data value −1367 kJ mol⁻¹: 25% out.
  • The apparatus uncertainties add to only about 3%, so most of the gap is systematic: heat lost to the air, incomplete combustion.
  • In Q = mcΔT, also check the assumptions: density of the water (or solution) 1.00 g cm⁻³, c = 4.18 J g⁻¹ K⁻¹, all the heat goes into the water.
Mission 2

Concordant titres, means and anomalies

  • Titres (cm³): rough 24.00 · 23.30 · 23.75 · 23.40 · 23.35.
  • Concordant: within 0.10 cm³ of each other: 23.30, 23.40, 23.35.
  • Leave out the rough titre and the anomaly (23.75).
  • Mean titre = (23.30 + 23.40 + 23.35) ÷ 3 = 23.35 cm³.
  • On a graph, an anomaly is a point far off the line: repeat it, or leave it out and say why.
Mission 2

Significant figures

  • × and ÷: give the answer to the same number of significant figures as the data value with the fewest.
  • Keep every digit until the final step: round only once.
  • Burette readings: 2 decimal places, last digit 0 or 5 (e.g. 23.45 cm³).
  • Too many figures claims precision you don't have; too few throws precision away.
Quick check
?A student dissolves 2.5 g of NaCl (M = 58.5 g mol⁻¹) in water and makes the solution up to 250.0 cm³. Which value of the concentration, in mol dm⁻³, is given to the appropriate number of significant figures?
Mission 2

Drawing and reading graphs

Graph anatomy: best-fit line, anomaly, gradient and intercept0102030405060020406080time / svolume / cm³anomalyΔxΔyintercept2 cm3gradient = Δy ÷ Δx
  • Independent variable on the x-axis; label each axis with quantity and unit.
  • Label style: quantity / unit, e.g. volume / cm³.
  • Scales: use most of the grid, in easy steps.
  • Line of best fit: straight or a smooth curve, points scattered either side; ignore anomalies.
  • Gradient = Δy ÷ Δx from a large triangle, with units. Intercept: where the line crosses the y-axis.
Quick check
?A student plots the volume of gas collected against time. The line of best fit is straight, but does not pass through the origin. It passes through (10 s, 14 cm³) and (50 s, 62 cm³). What is the gradient, in cm³ s⁻¹?
Mission check

?A student mixes two solutions in a polystyrene cup to find an enthalpy change. The thermometer has an uncertainty of ±0.5 °C per reading, and the temperature rises by only about 4 °C. Which change would most reduce the percentage uncertainty in the temperature change, ΔT?
Mission 3

Mission 3: Mix 10 g of hydrogen with 10 g of oxygen. Which runs out first?

Make a guess: Mix 10 g of hydrogen with 10 g of oxygen. Which runs out first?

Mission 3

Limiting and excess

Limiting reactant: 6 CO and 4 O₂ give 6 CO₂ with 1 O₂ left over2CO + O₂ → 2CO₂BeforeAfterO₂ left over6 CO + 4 O₂6 CO₂ + 1 O₂6 CO use 3 O₂, so CO limitsCO
  • The limiting reactant is used up first, and the reaction stops.
  • So it fixes the maximum amount of product.
  • The other reactant is in excess: some is left over.
  • 2CO + O2 → 2CO2, starting with 6 CO and 4 O2: 6 CO2 form, and 1 O2 is left over.
Mission 3

Finding the limiting reactant

  • Convert every reactant to moles. Masses alone tell you nothing.
  • Divide each amount by its coefficient in the equation. The smallest result is the limiting reactant.
  • Calculate all products from the limiting reactant only.
  • Excess left over = amount present − amount that reacted.
Mission 3

Worked example: burning methane

  • CH4(g) + 2O2(g) → CO2(g) + 2H2O(l), with 8.00 g of CH4 and 24.0 g of O2.
  • n(CH4) = 8.00 ÷ 16.0 = 0.500 mol; ÷ 1 = 0.500.
  • n(O2) = 24.0 ÷ 32.0 = 0.750 mol; ÷ 2 = 0.375. Smaller, so O2 limits.
  • n(CO2) = 0.750 ÷ 2 = 0.375 mol; mass = 0.375 × 44.0 = 16.5 g at most.
  • CH4 left = 0.500 − 0.375 = 0.125 mol = 2.00 g.
  • The smaller mass (methane) was the one in excess.
Quick check
?Nitrogen and hydrogen react: N2(g) + 3H2(g) → 2NH3(g). A mixture contains 5.60 g of N2 and 1.50 g of H2. Which statement is correct? (Aᵣ: H 1.0, N 14.0)
Mission 3

Theoretical and experimental yield

  • Theoretical yield: the maximum mass of product, calculated from the limiting reactant.
  • Experimental (actual) yield: the mass of product actually obtained. It is normally less.
  • Percentage yield = experimental yield ÷ theoretical yield × 100.
  • Why less: incomplete or reversible reaction, side reactions, product lost in transfer and purification.
  • Above 100%? The product is impure, for example still wet.
Quick check
?Which statement describes the theoretical yield of a product in a reaction?
Mission 3

Worked example: percentage yield

Percentage yield flow4.00 g CuO40.0 cm³ of1.00 mol dm⁻³ H₂SO₄÷ 79.5c × V0.0503 molCuO0.0400 molH₂SO₄÷ coefficients0.0503 ÷ 1 vs 0.0400 ÷ 1smaller: H₂SO₄ is limiting× 249.6 g mol⁻¹theoretical yield0.0400 × 249.6 = 9.984 g7.50 g collectedpercentage yield7.50 ÷ 9.984 × 100 = 75.1%
  • CuO(s) + H2SO4(aq) → CuSO4(aq) + H2O(l); crystallising gives CuSO4·5H2O.
  • 4.00 g CuO: n = 4.00 ÷ 79.5 = 0.0503 mol. 40.0 cm³ of 1.00 mol dm⁻³ acid: n = 0.0400 mol.
  • Ratio 1 : 1, so H2SO4 limits. The excess CuO is filtered off.
  • Theoretical yield: 0.0400 mol × 249.6 g mol⁻¹ = 9.98 g of CuSO4·5H2O.
  • 7.50 g collected: percentage yield = 7.50 ÷ 9.984 × 100 = 75.1%.
Calculate
?Copper(II) oxide is reduced by hydrogen: CuO(s) + H2(g) → Cu(s) + H2O(g). With hydrogen in excess, 3.98 g of CuO gives 2.85 g of copper. Calculate the percentage yield. (Aᵣ: O 16.0, Cu 63.5)
Mission check

?Thermite is a mixture of aluminium and iron(III) oxide. 2Al(s) + Fe2O3(s) → Al2O3(s) + 2Fe(l). A mixture of 10.0 g of Al and 10.0 g of Fe2O3 reacts, and 5.60 g of iron is collected. What is the percentage yield of iron? (Molar masses: Al 27.0, Fe2O3 159.6, Fe 55.8 g mol⁻¹)
Mission 4

Mission 4: Can a reaction with a 100% yield still turn most of its reactants into waste?

Make a guess: Can a reaction with a 100% yield still turn most of its reactants into waste?

Mission 4

Atom economy

  • Atom economy: the percentage of the reactants' total mass that ends up in the desired product.
  • Atom economy = molar mass of desired product ÷ sum of molar masses of all products × 100%.
  • Mass is conserved, so the reactant total equals the product total: either gives the same answer.
  • Multiply each M by its coefficient in the balanced equation.
  • It is fixed by the equation. The masses used and the yield do not change it.
Mission 4

Worked example: limestone to lime

Atom economy bar for CaCO₃ giving CaO and CO₂CaCO₃ → CaO + CO₂Reactant: 100.1 g of CaCO₃56.0%44.0%CaO: 56.1 gdesired productCO₂: 44.0 gby-productAtom economy = 56.1 ÷ 100.1 × 100 = 56.0%even at 100% yield, 44.0% of the mass is CO₂
  • CaCO3(s) → CaO(s) + CO2(g). Desired product: CaO (lime).
  • M: CaCO3 100.1; CaO 56.1; CO2 44.0.
  • Atom economy = 56.1 ÷ 100.1 × 100 = 56.0%.
  • So 44% of the mass leaves as CO2, even at 100% yield.
  • An addition reaction with a single product has 100% atom economy.
Quick check
?Which statement about atom economy and waste in an industrial process is correct?
Calculate
?In an older industrial process, titanium was made by reducing titanium(IV) chloride with sodium: TiCl4 + 4Na → Ti + 4NaCl. Calculate the atom economy for producing titanium, as a percentage. (Aᵣ: Na 23.0, Cl 35.5, Ti 47.9)
Quick check
?Which reaction has an atom economy of 100% for the product named?
Mission check

?Hydrogen is manufactured by reacting methane with steam: CH4(g) + H2O(g) → CO(g) + 3H2(g). In one batch, 16.0 kg of methane gave 4.80 kg of hydrogen. What is the atom economy for producing hydrogen by this reaction? (Aᵣ: H 1.0, C 12.0, O 16.0)
Mission 5

Mission 5: Why would a chemist pick a glass tube with just one mark over one marked all the way up?

Make a guess: Why would a chemist pick a glass tube with just one mark over one marked all the way up?

Mission 5

Choosing glassware

Volumetric glasswaremarkfillermark050VolumetricpipetteVolumetricflaskBuretteMeasuringcylinder25 cm3±0.06 cm3250 cm3±0.3 cm3any volume100 cm3±1.0 cm3eye levelbottom ofmeniscuson the markburetteconicalflaskwhite tile
  • Volumetric pipette (one mark): delivers one fixed volume with a very small uncertainty.
  • Volumetric flask (one mark): contains one exact volume: for making solutions.
  • Burette (marked all the way): delivers any volume, read to small divisions.
  • Measuring cylinder: quick and approximate.
  • One mark = one job, done precisely. Many marks = flexible, less precise per reading.
  • Typical uncertainties: 25 cm³ pipette ±0.06 cm³; 250 cm³ flask ±0.3 cm³; 100 cm³ measuring cylinder ±1.0 cm³ (class B).
Mission 5

Titration technique

Volumetric glasswaremarkfillermark050VolumetricpipetteVolumetricflaskBuretteMeasuringcylinder25 cm3±0.06 cm3250 cm3±0.3 cm3any volume100 cm3±1.0 cm3eye levelbottom ofmeniscuson the markburetteconicalflaskwhite tile
  • Rinse the pipette and burette with the solutions they will hold (not water).
  • Pipette: use a pipette filler; fill until the bottom of the meniscus sits on the mark, at eye level. Let it drain; touch the tip to the liquid surface; don't blow out the last drop.
  • Burette: remove the funnel; run liquid through the tap to clear air bubbles; read the bottom of the meniscus at eye level.
  • Conical flask on a white tile; add a few drops of indicator; swirl.
  • Add dropwise near the end point. Do a rough titration, then repeat until titres are concordant.
  • Record burette readings to 2 decimal places (ending in 0 or 5).
Mission 5

Making a standard solution

  • Weigh the solid by difference: weigh the container full, tip the solid into a beaker, reweigh the container.
  • Dissolve in a little distilled water in the beaker.
  • Pour into a volumetric flask through a funnel; rinse the beaker and funnel into the flask.
  • Add distilled water until the bottom of the meniscus is on the mark: the last part dropwise, at eye level.
  • Stopper and invert several times to mix.
Quick check
?A student needs to add exactly the same volume of sodium hydroxide solution to each of four conical flasks, ready for titration. Which piece of apparatus should the student use?
Mission 5

Heating safely and evenly

  • Water bath: gentle, even heating below 100 °C; a thermostatic bath holds a set temperature.
  • Electric heater (heating mantle or hotplate): no flame, so use it for flammable liquids.
  • Sand bath: even heating to higher temperatures.
  • Bunsen burner: never near flammable organic liquids.
  • Heating for a long time without losing volatile liquids: reflux, with a condenser.
Mission 5

Measuring gas, mass, time and temperature

Collecting gasGas syringeOver watergasmeasuring cylinderMass lossgcotton woolgas escapes
  • Gas syringe: collects gas directly; good for gases that dissolve in water.
  • Over water: gas pushes water out of an upturned burette or measuring cylinder. Not for very soluble gases (e.g. NH3, HCl).
  • Mass loss: flask on a balance; the gas escapes; a cotton wool plug stops spray.
  • Time with a stopwatch; temperature with a thermometer or a temperature probe.
Mission 5

Hazards and control measures

Hazard symbolsCorrosiveeye protection,glovesFlammableno naked flames;water bath or heaterToxicsmallest amounts,fume cupboardIrritant / harmfuleye protection, gloves;clean up spills at once
  • Hazard: what could cause harm. Risk: the chance of harm, given how you use it.
  • Corrosive / irritant: eye protection, gloves; clean up spills at once.
  • Flammable: no naked flames; water bath or electric heater.
  • Toxic (or harmful vapour): smallest amounts, fume cupboard.
  • Read the hazard data first (e.g. a safety data sheet), then choose a control measure for each hazard.
  • Justify each measure from the data: e.g. use a more dilute solution, or a smaller quantity, if the method still works.
Quick check
?A student must heat a reaction mixture containing ethanol (highly flammable, boiling point 78 °C) for 30 minutes. Which plan best controls the risk?
Mission 5

Planning an investigation

  • Independent variable: what you change. Dependent variable: what you measure.
  • Control variables: what you keep the same, and how (e.g. a water bath for temperature).
  • Choose a sensible range and number of values; plan repeats.
  • Write numbered steps, with apparatus chosen for the precision needed.
Mission 5

Evaluating a method

Fixing a limitationheat lossopen cupheat escapeslid + insulationless heat lostgas lossacid addedbefore bunggas escapesacid in small tube;fit bung, then tipno gas lost
  • Find the limitation: which step causes error, and in which direction?
  • Systematic? Fix the method; repeats won't help.
  • Random? Repeat and average, or use more precise apparatus.
  • Gas lost before the bung goes in → keep the reactants apart until sealed (e.g. a small tube of acid inside the flask, then tip).
  • Heat lost from a cup → lid and insulation, or extrapolate a cooling curve.
  • Small readings → measure larger quantities, to cut % uncertainty (see Mission 2).
  • Each improvement must match a specific limitation.
Quick check
?A student reacts pure calcium carbonate chips with excess hydrochloric acid and collects the carbon dioxide over water in an upturned measuring cylinder. The acid is tipped in from a small tube only after the bung is fitted. In every repeat, the volume of gas is lower than calculated. Which improvement deals with the most likely cause?
Mission check

?Before a redox titration, a student must add about 10 cm³ of dilute sulfuric acid to each conical flask. The acid is in excess, and its exact volume does not affect the result. Which apparatus is the best choice?
Recap

The big ideas

Mission 1

  • Back titration: acid reacted = acid added − acid left over; then use the equation's ratio.
  • With dilutions and portions, track moles step by step and scale (× 10 for a 25 of 250 portion).

Mission 2

  • % uncertainty = uncertainty ÷ value × 100; two readings → double the uncertainty; multiply or divide → add % uncertainties.
  • Repeats reduce random error; only a better method removes systematic error.

Mission 3

  • Moles ÷ coefficient: the smallest is the limiting reactant. It fixes the theoretical yield.
  • Excess left = amount present − amount reacted.
  • Percentage yield = experimental ÷ theoretical × 100.

Mission 4

  • Atom economy = M(desired product) ÷ total M of reactants (= total M of products) × 100, using coefficients.
  • It is set by the equation: a 100% yield can still waste most of the mass as by-product.

Mission 5

  • Volumetric pipette and flask: one exact volume. Burette: precise variable volume. Cylinder: quick and approximate.
  • Control each hazard with a measure that fits it; fix systematic errors by changing the method.
🏆

Mini-lesson complete!

⭐⭐⭐

You've worked through Formulae, Equations and Amounts of Substance (part 2) for Edexcel A-level Chemistry. 🎉

  1. Mission 1How can you titrate a tablet that won't even dissolve in water?
  2. Mission 2Why does the same balance give a less trustworthy result when you weigh a tiny amount?
  3. Mission 3Mix 10 g of hydrogen with 10 g of oxygen. Which runs out first?
  4. Mission 4Can a reaction with a 100% yield still turn most of its reactants into waste?
  5. Mission 5Why would a chemist pick a glass tube with just one mark over one marked all the way up?

Your stars: 0 / 0

📣 Smashed it? Share your score

Challenge a friend to beat your stars, or show a parent how you got on.

→ Back to A-Level Chemistry · Edexcel