← A-Level Chemistry · CCEA · A-Level Chemistry revision
⭐ 0
CCEA GCE Chemistry · Unit A2 2 / 5.4 Chromatography
Mini-Lesson

Chromatography

1 missions. Guess, learn, then check. Your place is saved.

  1. Mission 1Why do the dyes in one drop of ink travel different distances up the same strip of paper?
Mission 1

Mission 1: Why do the dyes in one drop of ink travel different distances up the same strip of paper?

Make a guess: Why do the dyes in one drop of ink travel different distances up the same strip of paper?

Mission 1

Two phases

Mobile and stationary phasesstationary phasemobile phasemostly heldmostly carriedfurther
  • Chromatography separates the components of a mixture between two phases.
  • Mobile phase: moves (a liquid solvent, or a gas).
  • Stationary phase: stays put (paper, a coated plate, a packed column).
  • Each component keeps switching: dissolved in the mobile phase ↔ held by the stationary phase.
  • More time in the mobile phase → it moves further (or comes out sooner).
Mission 1

Running a TLC or paper chromatogram

TLC set-up and developed platesolventoriginlidoriginsolventfront
  • Draw the origin line in pencil (ink would itself separate).
  • Spot the mixture and reference samples on the line; let the spots dry.
  • Stand the plate in solvent below the origin (or the spots dissolve away into the solvent).
  • Cover the tank: the air inside stays saturated with solvent vapour.
  • Remove before the solvent reaches the top; mark the solvent front at once.
  • Colourless spots: view under UV light (plates with a fluorescent coating), or use iodine vapour or a locating spray.
  • Safety: solvents are often flammable and harmful: no flames, use a fume cupboard; never look into the UV lamp.
Mission 1

Why some components move less

Why polar molecules are held by silicasolventsurface with –OH groupsOHOHOHOHCH3CH2OHH-bondpolar: heldnon-polar: carried
  • Silica (TLC) and paper both have many polar –OH groups on their surface (paper: cellulose, with water held on it).
  • Polar components are held strongly (dipole–dipole forces, hydrogen bonds): they move less.
  • Less polar components spend more time in a less polar solvent: they move further.
  • So the order of spots tells you the relative polarity of the components.
  • Mass is not the main cause: a small polar molecule can stay behind a large non-polar one.
Quick check
?The dyes in a black ink are separated by paper chromatography. Which difference between the dyes is mainly responsible for the separation?
Mission 1

Rf values

TLC set-up and developed platesolventoriginlidoriginsolventfront2.9 cm7.6 cm
  • Rf = distance moved by the spot ÷ distance moved by the solvent front, both from the origin.
  • Measure to the centre of the spot.
  • Rf has no units and lies between 0 and 1.
  • Example: spot 2.9 cm, solvent front 7.6 cm: Rf = 2.9 ÷ 7.6 = 0.38.
  • Rf depends on the solvent, the plate and the temperature: compare with standards run on the same plate.
Quick check
?On a TLC plate, the solvent front is 6.4 cm above the origin line, which is 1.0 cm above the bottom edge of the plate. The centre of spot S is 4.8 cm above the origin; its top edge is 5.1 cm above the origin. What is the Rf value of S?
Mission 1

Two-way paper chromatography

Two-way paper chromatography123solvent 1solvent 2startsolvent 1turn 90°,solvent 2
  • Two components can have almost the same Rf in one solvent and stay as one spot.
  • Spot the mixture near one corner; run in solvent 1; dry.
  • Turn the paper 90°; run in solvent 2.
  • Spots that overlapped now spread across the paper.
  • Each spot has two Rf values, one for each solvent: match both to identify it.
Mission 1

Chromatography in a column

Column methodsGas–liquid chromatography (GLC)carriergasinjectorheated ovendetectorrecorder
  • Gas chromatography (GC): an unreactive carrier gas (the mobile phase) pushes the vaporised sample through a long, heated column.
  • Stationary phase: a solid, or (usually) a high-boiling liquid coated on a solid support or on the column wall.
  • CCEA calls this gas–liquid chromatography (GLC).
  • Retention time: time from injecting the sample to the component reaching the detector.
Mission 1

Reading a gas chromatogram

Gas chromatogram0123456detector signaltime / min1.41.82.75.44.310.8illustrativenumbers = peak areas
  • Each peak = one component. Same retention time as a standard (same conditions) → likely the same substance.
  • Retention time depends on column temperature, gas flow rate and the stationary phase: keep them the same.
  • Peak area is proportional to the amount of that component.
  • % of a component = its peak area ÷ total peak area × 100 (assuming the detector responds equally to each).
  • Example: areas 1.8, 5.4, 10.8 → total 18.0 → 10%, 30%, 60%.
Mission 1

GC–MS: separate, then identify

GC–MS: separate, then identifyGCseparatesretention timeeach peakenters the MSmassspectrometeridentifiesabundancem/zmatch to a databaseof known spectra
  • GC separates the mixture; each component flows straight into a mass spectrometer.
  • Its mass spectrum (M⁺ and fragments) is matched to a database of known spectra.
  • Retention time + mass spectrum: a much more certain identification than either alone.
  • Uses: forensics, drug testing (e.g. in sport), checking purity.
  • Purity by TLC: your aspirin vs commercial aspirin. A pure sample gives one spot at the same Rf; an extra spot means an impurity (e.g. unreacted 2-hydroxybenzoic acid).
Quick check
?A gas chromatogram of a mixture of three esters, P, Q and R, gives peak areas P 2.4, Q 3.6 and R 6.0 (arbitrary units). Assume the detector responds equally to each ester. What is the percentage of Q in the mixture?
Mission check

?A student runs TLC of a mixture of two polar compounds on a silica plate, using hexane as the solvent. Both spots barely leave the origin. Which change is most likely to make the spots move further up the plate and separate?
Recap

The big ideas

Mission 1

  • Components separate because each is attracted differently to the stationary phase and the mobile phase.
  • Rf = spot distance ÷ solvent-front distance; retention time identifies GC peaks; compare with standards under the same conditions.
🏆

Mini-lesson complete!

⭐⭐⭐

You've worked through Chromatography for CCEA A-level Chemistry. 🎉

  1. Mission 1Why do the dyes in one drop of ink travel different distances up the same strip of paper?

Your stars: 0 / 0

📣 Smashed it? Share your score

Challenge a friend to beat your stars, or show a parent how you got on.

→ Back to A-Level Chemistry · CCEA